IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following warnings should be observed.
3500 Pelco Way,
Clovis, CA 93612-5699
USA
1. Installation and servicing should only be done by qualified service personnel and
conform to all local codes.
In North America & Canada:
Tel (800) 289-9100
FAX (800) 289-9150
2. Installation shall be done in accordance with all local and national electrical and
mechanical codes utilizing only approved materials.
International Customers:
Tel (1-559) 292-1981
FAX (1-559) 348-1120
3. Use only installation methods and materials capable of supporting four times the
maximum specified load.
4. Use stainless steel hardware to fasten the mount to outdoor surfaces.
5. To prevent damage from water leakage when installing a mount outdoors on a roof or
wall, apply sealant around the bolt holes between the mount and mounting surface.
U
®
L
LISTED
The product and/or manual may bear the following marks:
This symbol indicates that danger-
ous voltage constituting a risk of
electric shock is present within
C A U T I O N :
this unit.
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there
are important operating and main-
tenance instructions in the litera-
ture accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
DESCRIPTION
The PM200C is a light duty ceiling/pedestal mount designed for mounting light duty scanners
and pan/tilts and is capable of handling loads up to 25 pounds (11.25 cm). The PM200C is
designed for easy installation or removal and mounts to any horizontal surface.
INSTALLATION
When mounting the PM200C ceiling/pedestal mount make certain that the mounting surface is
capable of supporting the full load of the mount, scanner, or pan/tilt and camera.
NOTE: The two fasteners to
secure the mount to the
mounting surface (minimum 1/4"
diameter recommended) and the
three fasteners to secure a
scanner (10-32 x 1.00") to the
mount are not supplied. The
three 1/4-20 x .625 Hex head
bolts, flat washers and split lock
washers for a pan/tilt are
1. Drill holes in the mounting surface using the mount as a template and attach the mount
securely with the recommended fasteners. (Refer to Figure 1 for mounting dimensions.)
If you install the mount outdoors, rain water could leak through the holes for the mounting
bolts and damage the roof. This could be a problem only if the mounting bolts go
completely through the roof.
To prevent water damage, seal the bolt holes with an appropriate sealant. Apply the
sealant around the bolt holes between the mount and the mounting surface.
2. Attach the scanner or pan/tilt to the mount with the recommended fasteners.
supplied.
HARDWARE KIT
Qty
3
5
5
2
Description
Part Number
1/4-20 x 5/8, Hex head bolts
3/16 special size, flat washer
1/4" washer, split lock
1/4-20 nut
ZH1/420X.625CH
ZH260X562X65C
ZH1/4LWSSL